The inQuiQ, biomolecular interaction analysis for binding affinity and kinetics
The inQuiQ brings integrated photonics to biomolecular interaction analysis. By placing most of the optics on the sensor chip, we ensure signal stability while creating a highly sensitive benchtop instrument with a modular upgrade path for higher throughput.
The inQuiQ at a glance
Front view
Model: inQuiQLabel-free biosensor
01Cover the full affinity range
10 pM to 10 mM
02Fits on your bench
30 × 36 × 40 cm, 18 kg
03Give slow binders more time
Injections from 30 μL to 2 mL
04See the small signals
Noise below 0.1 RU RMS
05Run serum and plasma samples
Antifouling hydrogel surface
06Modular upgrade path
Up to 768 samples
01Sample + surface chemistry
Designed around diverse samples and surface chemistries
Sample compatibility
Diverse molecule types across one platform
Molecular scale
100 Da50 kDa150 kDaparticles
Surface chemistry
Choose the coupling strategy for your ligand
Amine coupling
Covalent coupling to carboxyl groups via EDC/NHS
Streptavidin / NeutrAvidin
Capture biotinylated ligands
Protein A and G capture
Immunoglobulin workflows
Streptactin and NTA
Capture Strep-tagged and his-tagged proteins
Lipid layers
Membrane proteins or lipid-interacting molecules
Azide groups
Click-based chemistry
02Chip + flowcell
Addressable flow channels for KD determination
- Four channels with customizable flow paths
- 4-plex assays with in-flow immobilization, up to 16-plex with a spotter
- Antifouling hydrogel surface for clean signals in complex media
- 1 to 100 µL/min flow, up to 300 µL/min for low-viscosity samples
1–16 · sensor spots · pink · binding event
03Detection + performance
The chip: where the magic happens
NES photonic detection
performance
04Data + software
Intuitive software for multi and single-cycle kinetics
Affinity
Steady-state binding and equilibrium dissociation constant (KD) analysis
Kinetics
ka, kd, and KD interpretation from the sensorgram
Quantification
Concentration and biologically active concentration
Specificity
Screening, epitope binning, thermodynamics, yes/no binding
05inQuiQ specifications
Specifications
02Minimum sample volume
from 30 µL sample
and 5 µL injection volume
03Sample handling
10 × 2 mL tubes
1.5 mL generic tubes compatible
04Channels
4 channels, each containing 4 sensors
05Temperature control
16 °C to 40 °C
06Output
Real-time binding response
Sample handling
- Channels
- 44 sensors each
- Sample capacity
- 10 × generic 1.5 or 2 mL tubes
- Minimum sample volume
- 30 µL50 µL recommended
- Injection volume range
- 30 µL to 2 mL
- Flow rate range
- 1 to 100 µL/minup to 300 µL/min for low-viscosity samples
Sensing
- Sensor chip
- HC1000M, HC30M
- Data collection rate
- 1 Hzsensitivity chips 1, 10, 100 Hzhigh-sensitivity chips
- Baseline noise
-
Typically < 0.1 RU RMSsensitivity chips
Typically < 0.01 RU RMSat 1 Hz, high-sensitivity chips*
*Coming soon - Baseline drift
- < 0.3 RU/mintypically
Measurement range
- Association rate constant, ka
- 101 to 107 M-1s-1
- Dissociation rate constant, kd
- 1 to 10-6 s-1
- Affinity, KD
- 10 pM to 10 mM
- Sample refractive index range
- Unlimited
Buffers and physical
- Running buffer capacity
- 2 × 50 mL
- Regeneration buffer capacity
- 1 × 50 mL
- Temperature control
- 16 to 40 °Cmax 4 °C below ambient
- Dimensions, W × H × D
- 30 × 36 × 40 cm
- Net weight
- 18 kg