Skip to main content
Delta Life Science

GPCR ligand binding and membrane protein kinetics, in a lipid environment

Take a receptor out of the membrane and it stops behaving like itself. Expression yields are low, the lipid environment is fragile, and there is rarely enough material for a second attempt. Lipid bilayer sensors on the inQuiQ make GPCR ligand binding measurable on a receptor that stays in its lipid environment.
Sensitive detection at 0.1 RU RMS baseline noise
From 30 µL of sample per injection
Temperature control from 16 to 40 °C

Applications in membrane protein drug discovery

Receptor ligand kinetics reveal selectivity and residence time, while membrane targets are harder to characterize. The inQuiQ supports GPCR ligand binding in lipid environments, with label-free analysis for GPCR binding and receptor binding kinetics.

GPCR ligand binding

Roughly a third of approved drugs act on a GPCR.

Build a GPCR binding assay that measures ligand association and dissociation against the receptor.

receptor-ligand kinetics lipid bilayer

Ion channel binding assays and transporters

Characterize binding to channels and solute carriers.

modulator ranking

Receptor tyrosine kinases

Work with EGFR, HER2, and related receptors.

Measure antibody or ligand binding to the ectodomain and compare binding affinity and kinetics.

EGFR, HER2

Cytokine and Fc receptors

Measure engagement at the cell-surface receptor.

Compare candidate variants against the same receptor preparation.

variant ranking

Nanodisc and SMALP preparations

Confirm that nanodisc reconstitution leaves the receptor still binding.

Check a new preparation before a larger campaign.

nanodisc capture

Benefits of the inQuiQ in membrane protein analysis

01 / 04

One injection, four channels, sixteen sensors

Four independently addressable flow channels, each carrying four sensors, with the sample flowing through the channels in series.

30 µL minimumsequential flow paths
In-flow immobilization
Spotter immobilization

Run a lipid binding assay in a lipid environment

Membrane proteins need a sensor surface built for them, either compatible with a lipid mono- or bilayer, or able to capture a nanodisc with the receptor still functional.

lipid-compatible surfacenanodisc capture
bilayer, or captured nanodisc

Read a small response from a low-yield preparation

Expression yields for membrane proteins are usually low, so the binding response is small. Baseline noise sits at 0.1 RU RMS, and the sensor is regenerated between injections rather than replaced.

0.1 RU RMS30 µL
small response, low noise

Watch receptor ligand kinetics and binding affinity

The sensorgram gives the full kinetics picture. Binding ffinity runs from 10 pM to 10 mM, with steady-state fitting where dissociation is too fast for kinetics.

ka, kd, KD10 pM to 10 mM
association, then dissociation

How a membrane protein binding run works

Every measurement on a lipid bilayer sensor follows the same steps. The receptor is immobilized in a lipid bilayer on the sensor, the ligand flows past, and the response is recorded through the whole injection.

Immobilization

The receptor is delivered into a bilayer formed across the sensor.

For GPCR and membrane protein binding kinetics analysis, proteoliposomes fuse on the chip to leave a continuous supported bilayer over the waveguide, with the receptor sitting in it in native orientation.

  • vesicle fusion
  • supported bilayer

Deactivation

Bare patches left in the layer are blocked before the first ligand sample arrives.

Defects expose the surface underneath, and detergent, free lipid, and buffer components adsorb there readily. That appears in the sensorgram as non-specific binding rather than as receptor engagement.

  • bilayer defects
  • blocking
  • non-specific binding

Association

The ligand flows across the surface and the response climbs.

The association phase gives the on-rate, ka, for receptor-ligand binding. A reference channel carrying a protein-free bilayer of the same lipid composition separates ligand binding from binding to the membrane itself.

  • protein-free bilayer reference
  • referencing
  • ka

Dissociation

Buffer replaces the ligand and the response falls as the complex comes apart.

The dissociation phase gives kd, and 1/kd gives residence time, the number that separates two GPCR ligands sharing a KD. Single-cycle kinetics runs the series uninterrupted when the preparation is scarce.

  • residence time
  • kd
  • KD
  • SCK

Regeneration

A mild regeneration buffer returns the sensor to baseline for the next ligand.

The bilayer and the receptor in it stay intact, so every ligand meets the same surface. Conditions are kept gentle, since the lipid environment is what makes the measurement worth having.

  • mild regeneration
  • bilayer stability
  • automated cycling
Response (RU) Time

What the inQuiQ does for membrane protein work

Six capabilities, one modular benchtop instrument, in a label-free workflow.

Many constructs, one limited prep

Four channels with in-flow immobilization, or sixteen sensors with a spotter, compare constructs and controls from one injected sample.

16 sensors (spotter required) 30 µL

Detect low-abundance targets

Baseline noise stays low enough that a small binding response is still readable.

0.1 RU RMS

Full kinetics from limited material

One affinity range covers weak modulators through tight ligands, with kon and koff from the same injection series.

10 pM to 10 mM

A surface that holds a membrane

Sensor surfaces compatible with lipid mono- and bilayers, or able to capture nanodiscs, keep the receptor functional.

lipid-compatible surface nanodisc capture

Stable across a long series

The temperature-controlled flow cell holds conditions steady while a fragile preparation is measured over many injections.

temp. control from 16 to 40 °C

Modular system for an increased throughput

Simply add an autosampler, and run a long construct or condition series unattended.

2×96 wells 2×384 wells
Explore the inQuiQ768
Start A conversation

Talk to an application scientist

Bring your receptor. We will tell you honestly whether label-free is the right method for it, and how the assay would be built.

Ready to see the inQuiQ in action?

Questions researchers ask

Capture the receptor on a lipid-compatible sensor surface, or capture the nanodisc carrying it, then inject the ligand across a concentration series. The association phase gives kon, the dissociation phase gives koff, and the two together give KD. Affinity on the inQuiQ runs from 10 pM to 10 mM.

Keep it in a lipid environment. Detergent micelles, nanodiscs, and SMALPs all preserve the folded receptor, and the sensor surface has to suit them. A standard hydrogel chip does not, so membrane work uses a surface built for lipid mono- and bilayers or for nanodisc capture.

Yes, on a label-free biosensor with a sensor surface designed for it. The particle is captured through a tag on the receptor or on the scaffold, and the ligand is then injected over it. A reference channel carrying empty particles separates binding to the receptor from binding to the lipid or the scaffold.

The inQuiQ runs from 30 µL of sample per injection. Sensors are regenerable, so one prepared surface carries a series of ligands, concentrations, and controls rather than one measurement per surface. That matters when expression yield is the limit on the experiment.

Affinity (KD) says how tightly ligand and receptor bind at equilibrium. Kinetics says how they get there: kon for how fast the complex forms, koff for how fast it falls apart. A receptor ligand binding assay reported as KD alone hides that, because two ligands with the same KD can have very different residence times.

Cookie settings

Choose which optional tools we may use. You can change your choice at any time through "Cookie settings" at the bottom of every page. Privacy policy

Strictly necessary

Always on

Needed for the website to work, such as remembering your cookie choice. These cannot be switched off.

  • Cookie consent choice: Stores your consent choice in your browser so we do not ask again on every page.

Privacy-friendly statistics

Always on

Anonymous visitor statistics with little or no privacy impact. IP addresses are anonymised, no cross-site profiles are built, and the data is not shared for other purposes.

  • Matomo: Anonymous visitor statistics with anonymised IP addresses.
  • Ahrefs Web Analytics: Cookie-free visitor statistics. No personal data is collected.

Analytics

Helps us understand how visitors use the site, for example through heatmaps or session recordings. These tools may set cookies and process your IP address.

  • Microsoft Clarity: Heatmaps and session recordings that show how visitors navigate the site. Provider: Microsoft.

Marketing

Used to measure and improve our advertising, for example on Google or LinkedIn. These tools may set cookies and share data with the advertising platform.

  • OpenAI Ads Pixel: Measures the results of ChatGPT advertising campaigns. Provider: OpenAI.

Region detection: IP Geolocation by DB-IP